ABB Digital I O Module AI893 3BSC690141R1 ABB S800 I/O modules 500 V a.c.
U0 (Groups CENELEC USA) | IIC |
I0 (Groups CENELEC USA) | IIB |
P0 (Groups CENELEC USA) | IIA |
U0 - C0 (uF) | 1.41 |
U0 -L0 (mH) | 88 |
U0 -L/R (uH/O) | 586 |
I0 - C0 (uF) | 9 |
I0 -L0 (mH) | 352 |
I0 -L/R (uH/O) | 2347 |
P0 - C0 (uF) | 36 |
P0 -L0 (mH) | 706 |
P0 -L/R (uH/O) | 4707 |
CE mark | Yes |
Electrical safety | IEC 61131-2, FM |
Hazardous Location | C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2 |
Marine certification | - |
Protection rating | IP20 according to IEC 60529 |
Corrosive atmosphere ISA-S71.04 | G3 |
Climatic operating conditions | 0 to +55 °C (Storage -40 to +70 °C), RH=5 to 95 % no condensation, IEC/EN 61131-2 |
Pollution degree | Degree 2, IEC 60664-1 |
Mechanical operating conditions | IEC/EN 61131-2 |
EMC | EN 61000-6-4, EN 61000-6-2 |
Overvoltage categories | IEC/EN 60664-1, EN 50178 |
Equipment class | Class I according to IEC 61140; (earth protected) |
Max ambient temperature | 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F) |
RoHS compliance | EN 50581:2012 |
WEEE compliance | DIRECTIVE/2012/19/EU |
Resolution | 15 bit + sign |
Input impedance | >10 MΩ |
Isolation | Groupwise isolated from ground |
Error | TC/mV: <20 µV ; RTD (0-400 Ω): <0.1 Ω ; RTD (0-4000 Ω): <1 Ω |
Temperature drift | TC/mV: <20 µV/10°C ; RTD (0-400 Ω): <0.1 Ω/10°C ; RTD (0-4000 Ω): <1 Ω/10°C |
Update cycle time | (no of active channels) x 125 + 125 ms |
Common mode voltage input | +/- 5V |
CMRR, 50Hz, 60Hz | >100 dB |
NMRR, 50Hz, 60Hz | >80 dB |
Rated insulation voltage | 50V |
Dielectric test voltage | 500 V a.c. |
Power dissipation | 0.5 W |
Current consumption +5 V Modulebus | Typ. 90 mA, Max. <125 mA |
The AI893 Analog Input Module has 8 channels. The module includes Intrinsic Safety protection components on each channel for connection to process equipment in hazardous areas without the need for additional external devices.
The module can be configured for either 2 or 3-wire RTD sensors or for TC sensors. In TC mode, channel 8 be used for Cold Junction (ambient) temperature measurements, thus serving as CJ-channel for channel 1...7. The junction temperature may be measured locally on the MTUs screw terminals, or on a connection unit distant from the device. The cold junction temperature is measured with a 3-wire Pt 100 sensor. Alternatively, a fix junction temperature for the module may be set by the user (as parameter). Channel 8 may be used in the same manner as channel 1-7 when no CJ-temperature measurement is needed.
TU890 and TU891 Compact MTU can be used with this module and it enables three wire connection to the process devices without additional terminals. TU890 for Ex applications and TU891 for non Ex applications.
• 8 differential input channels for 2 or 3-wire RTD and Thermocouple.
• 1 group of 8 channels isolated from ground.
• 15 Bit + sign resolution.
• Ex certified inputs.
MORE INFORMATION
DELIVERY
Logistic partners UPS, FedEx and DHL
International delivery available
Same day dispatch from group stock
WARRANTY
All parts new are covered by Shenzhen Viyork 12 month warranty
RETURNS
No hassle returns policy
Dedicated customer support team
PAYMENT
Trade credit
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment options
We accept Bank transfers and the following methods of payment:
Western Union PayPal VISA
Shenzhen Viyork Technology CO.,LTD
Contact:Suki
Mobile:0086-13268302140
Whatsapp+852 9701 2657
Email:suki@viyorktech.com
Skype:suki@viyorktech.com
Address:1103,Block C,South Building,Luo Fang Road,Luohu District,Shenzhen,518001,China